Alinco EJ-50U Manual de Instruções Página 10

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 43
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 9
10
STREAMSW
STR $01 0-$7F Sets character used to change STREAM
9-1-2
TOUT TOUT 30 0-250 Message Board time-out parameter
10-1-3
TRACE TRAC OFF ON/OFF Displays the contents of all received frames.
4-7-6
TRANS T N/A N/A Enter the transparent mode.
6-3-1
TRFLOW TRF OFF ON/OFF Flow-control in the transparent mode. When ON,
control comes from the host program
6-3-2
TRIES TRI 0 0-15 Sets the number of attempts to re-send a packet that
has not been acknowledged as received.
4-4-9
TXDELAY TX 50 0-120 Designates the time delay between PTT and the
start of data transmission.
4-2-6
TXFLOW TXF OFF ON/OFF When OFF TNC determines flow-control while in
Transparent Mode
6-3-3
UICHECK UIC 28 0-250 Sets the time not to relay previously received UI
frames while in UI digipeat. Unit of 1s.
8-3-1
UIDIGI UI OFF ON/OFF,
Call1,Call2
, --,Call4
Call1 to Call4 Relays A UI Packet that does not
contain MYCALL and matches the set parameters.
The UIDIGI call will be replaced with MYCALL
8-3-3
UIDWAIT UIDW OFF ON/OFF Can be set if PRESET or DWAIT commands
become active in UI digipeat
8-3-2
UIFLOOD UIF Name,
ID/NOID
/FIRST
N/A Determines processing of packets being digipeated.
Decrements count in sequentially repeated packets
8-3-4
UISSID UIS OFF ON/OFF Determines if a special process is required when
matching UI frames to the default
8-3-6
UITRACE UIT N/A Name Determines the relay of UI packets and MYCALL is
not on the source list or on the relayed station list
Decrements count of sequentially repeated packets.
8-3-5
UNPROTO U CQ Call (VIA
call1,call2
, --,call8)
Sets the destination of packet and the DIGI-PEAT
route while communicating unconnected.
4-5-1
USERS US 1 0-10 Number of channels open for use in multi-
connections to the TNC.
9-1-1
WPATH WPATH
N/A Call1, --,
Call7
Sets digipeater station list to use when using
UISSID relay.
8-3-10
WRITE W N/A call Write message on the Message Board to CALL
10-2-5
XFLOW X ON ON/OFF Software flow / Hardware flow controls
3-2-6
3. Connecting to the host PC
3-1 Communications environment
Set the PC parameters as follows (9600,,8,N,1 are standard settings for most terminals and software programs.)
* Bit rate 9600Bps fixed (ABAUD)
* data length 8 bit / 7 bit AWLEN command
* Parity None/Even/Odd Parity command
* Stop bit 1 bit fixed
The following parameters must meet the terminal software’s requirements.
* wireless modem to the host: echo back setting Echo command
* wireless modem to the host: put [LF] after [CR] AUTOLF command
Vista de página 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 42 43

Comentários a estes Manuais

Sem comentários